about summary refs log tree commit diff
path: root/README.md
blob: 543d321b6a3bf765884848e56447f289b6f75332 (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
# prometheus-nano-exporter

A minimalistic exporter of node metrics for the Prometheus monitoring
system.

## Word of Warning

This is not an officially supported Google product. It's also
definitely not *used* by Google.

There are no particularly compelling reasons to use this software over
the alternatives. On a Real Computerâ„¢, the standard [Prometheus node
exporter](https://github.com/prometheus/node_exporter) is perfectly
adequate, and has a much larger feature set, not to mention adoption
rate. On OpenWRT, the standard community-supported package repository
already contains a lightweight Lua rewrite as
[prometheus-node-exporter-lua](https://openwrt.org/packages/pkgdata/prometheus-node-exporter-lua),
which is even smaller in disk footprint, if you don't count the Lua
interpreter.

The only reason why you would *need* this version is if you were
building for a particularly constrained system, and did not want to
include the Lua interpreter, or *any* foreign dependencies (other than
a C runtime library).

Other than that, you might choose to use it for æsthetic reasons.

## Installation

If you are able to compile code for your target system of choice, and
are happy to include all collectors, you may simply compile all the
`.c` files together.

You can also use the bundled `Makefile`, which likely requires GNU
Make. You can comment out collectors in the Makefile to leave them out
of the build if you don't need them.

TODO: OpenWrt feed + package definition + instructions.

The metrics collection is highly Linux-specific. You probably won't
have much luck on other operating systems.

## Collectors

For the most part, the produced metrics try to loosely (but not
slavishly) adhere to the format used by the standard Prometheus node
exporter (as of version v0.16).

This is an overview of the available collectors. See the [Collector
Reference](#collector-reference) below for detailed documentation,
including generated metrics, labels and configuration options.

| Name | Description |
| ---- | ----------- |
| [`cpu`](#cpu) | CPU usage from `/proc/stat` and CPU frequency scaling data from sysfs. |
| [`diskstats`](#diskstats) | Disk I/O statistics from `/proc/diskstats`. |
| [`filesystem`](#filesystem) | Statistics of mounted filesystems from `statvfs(2)`. |
| [`hwmon`](#hwmon) | Temperature, fan and voltage sensors from `/sys/class/hwmon`. |
| [`meminfo`](#meminfo) | Memory usage statistics from `/proc/meminfo`. |
| [`network`](#network) | Network device transmit/receive statistics from `/proc/net/dev`. |
| [`textfile`](#textfile) | Custom metrics from `.prom` text files dropped in a directory. |
| [`uname`](#uname) | Node information returned by the `uname` system call. |

## Usage

By default, all collectors are enabled. Use a command line argument of
the form `--{collector}-off` (e.g., `--cpu-off`) to selectively
disable specific collectors. Alternatively, if you explicitly enable
any collector with `--{collector}-on`, only such explicitly enabled
collectors are actually enabled. You probably don't want to mix both
`on` and `off` flags in the same invocation.

The general command line arguments are documented below. Specific
collectors may also accept further arguments, which will always have
the prefix `--{collector}-`. They are documented in the [Collector
Reference](#collector-reference) section.

| Flag | Description |
| ---- | ----------- |
| `--foreground` | Don't daemonize, but remain on the foreground instead. |
| `--pidfile=F` | After daemonizing, write the PID of the process to file at *F*. No effect if combined with `--foreground`. |
| `--port=X` | Listen on port *X* instead of the default port (9100). |

## Collector Reference

### `cpu`

Metrics and labels:

* `node_cpu_seconds_total{cpu=N,mode=M}`: Number of CPU seconds spent
  in various different modes, as reported in `/proc/stat`. *N* is the
  CPU index, a number between 0 and one less than the number of
  (logical) CPUs in the system. The mode *M* is one of `user`, `nice`,
  `system`, `idle`, `iowait`, `irq`, `softirq` or `steal`. There will
  be one row for each CPU and each mode in the scrape.
* `node_cpu_frequency_hertz{cpu=N}`: The current CPU clock frequency
  in Hertz at the time of the scrape. This is the
  `cpufreq/scaling_cur_freq` value under the CPU-specific sysfs
  directory.

### `diskstats`

The metrics correspond to the columns of `/proc/diskstats`:

* `node_disk_reads_completed_total`: Total number of successfully
  completed disk reads.
* `node_disk_reads_merged_total` Total number of adjacent reads merged
  together.
* `node_disk_read_bytes_total`: Total number of bytes read from the
  device.
* `node_disk_read_time_seconds_total`: Total time spent in read
  requests.
* `node_disk_writes_completed_total`: Total number of successfully
  completed disk writes.
* `node_disk_writes_merged_total`: Total number of adjacent writes
  merged together.
* `node_disk_written_bytes_total`: Total number of bytes written to
  the device.
* `node_disk_write_time_seconds_total`: Total time spent in write
  requests.
* `node_disk_io_now`: Number of I/O operations currently in progress.
* `node_disk_io_time_seconds_total`: Total time spent in disk I/O.
* `node_disk_io_time_weighted_seconds_total`: Time spent in disk I/O
  weighted by the number of pending operations.
* `node_disk_discards_completed_total`: Total number of discard
  operations completed successfully.
* `node_disk_discards_merged_total`: Total number of adjacent discard
  operations merged.
* `node_disk_discarded_sectors_total`: Total number of discarded
  sectors. Note that this is in sectors, not bytes, unlike the
  corresponding read/write metrics.
* `node_disk_discard_time_seconds_total`: Total time spent in discard
  operations.

See the kernel's
[Documentation/iostats.txt](https://www.kernel.org/doc/Documentation/iostats.txt)
for more details. The collector assumes the read/write totals are
reported using a sector size of 512 bytes.

All metrics have one label, `device`, containing the device name from
`/proc/diskstats`.

The `--diskstats-include=` and `--diskstats-exclude=` command line
arguments can be used to select which devices to report on. The format
for both is a comma-separated list of device names (e.g.,
`--diskstats-include=sda,sdb`). If an include list is provided, only
those devices explicitly listed are included. Otherwise, all devices
not mentioned on the exclude list are included.

### `filesystem`

Metrics:

* `node_filesystem_size_bytes`: Total size of the filesystem.
* `node_filesystem_free_bytes`: Number of free bytes in the
  filesystem.
* `node_filesystem_avail_bytes`: Number of free bytes available to
  unprivileged users.
* `node_filesystem_files`: Total number of inodes supported by the
  filesystem.
* `node_filesystem_files_free`: Number of free inodes.
* `node_filesystem_readonly`: Whether the filesystem is mounted
  read-only: `0` (rw) or `1` (ro).

Labels:

* `device`: Device node path mounted at the location.
* `fstype`: Mounted filesystem type.
* `mountpoint`: Location where the filesystem is mounted.

By default, all mounts where the device path starts with an `/` are
included. Command line arguments of the form
`--filesystem-{in,ex}clude-{device,type,mount}=X,Y,Z` can be used to
define comma-separated inclusion and exclusion lists for the device
path, filesystem type and mountpoint labels, respectively. Each of the
three categories is tested independently, and only if a mounted
filesystem passes all three tests, it is included in the metrics. For
each category, if an include list is specified, only the explicitly
listed values are accepted -- this overrides even the `/` prefix test
for devices. If an include list is not set, all values not on the
exclusion list are accepted.

The data is derived from scanning `/proc/mounts` and calling
`statvfs(2)` on all lines that pass the inclusion checks.

### `hwmon`

The `hwmon` collector pulls data from all the sysfs subdirectories
under `/sys/class/hwmon`. The supported entry types are temperature
(`temp*`), fan (`fan*` and voltage (`in*`) sensors.

Metrics:

* `node_hwmon_temp_celsius`: Current temperature in degrees Celsius.
* `node_hwmon_fan_rpm`: Current fan speed in RPM.
* `node_hwmon_fan_min_rpm`: Threshold for minimum fan speed.
* `node_hwmon_fan_alarm`: Active fan alarm signal: `0`/`1`.
* `node_hwmon_in_volts`: Input voltage measurement.
* `node_hwmon_in_min_volts`: Lower threshold for a voltage alarm.
* `node_hwmon_in_max_volts`: Upper threshold for a voltage alarm.
* `node_hwmon_in_alarm`: Active voltage alarm signal: `0`/`1`.

All the metrics have the same two labels: `chip` and `sensor`. The
`chip` label is derived from the sysfs directory path, while the
`sensor` label designates a specific sensor on the same (logical)
chip.

The values are by default directly as reported in sysfs: there's no
built-in scaling.

(TODO: potential future feature: configurable scaling via command line
options.)

### `meminfo`

The `meminfo` collector exposes all the rows from `/proc/meminfo`
under the metric name `node_memory_X`. The part *X* corresponds to the
label in `/proc/meminfo`, with the exception that non-alphanumeric
characters are replaced with `_`, and any remaining trailing `_`s are
removed.

If the line in `/proc/meminfo` has a `kB` suffix, the suffix `_bytes`
is also appended to the metric name, and the value multiplied by 1024
to convert it to bytes.

### `network`

Metrics and labels:

* `node_network_receive_X{device=D}`: Metrics related to receiving
  data on network interface *D*.
* `node_network_transmit_Y{device=D}`: Metrics related to sending data
  on network interface *D*.

The exact set of metrics (`X` and `Y` above) depends on the columns
included in your `/proc/net/dev` file. A normal set is:

| Receive | Transmit | Metric | Description |
| ------- | -------- | ------ | ----------- |
| X | X | `bytes` | Byte counter |
| X | X | `packets` | Packet counter |
| X | X | `errs` | Errors while receiving/transmitting |
| X | X | `drop` | Dropped frame count |
| X | X | `fifo` | ? |
| X |   | `frame` | ? |
| X |   | `compressed` | ? |
| X |   | `multicast` | Byte count |
|   | X | `colls` | Collisions while transmitting |
|   | X | `carrier` | ? |

By default, statistics are reported for all network interfaces except
the loopback interface (`lo`). The `--network-include=` and
`--network-exclude=` options can be used to define a comma-separated
list of interface names to explicitly include and exclude,
respectively. If an include list is set, only those interfaces are
included. Otherwise, all interfaces *not* mentioned in the exclude
list are included.

### `textfile`

The `textfile` collector can be used to conveniently export custom
node-bound metrics. Metrics in any files ending in `.prom` in the
designated directory are included in the scrape. Generally you should
write to a file with a different suffix (say `.prom.tmp`) and then
atomically rename the file, to prevent the server for sending data
from incomplete metrics files.

The implementation in this program copies the file contents directly
to the outgoing HTTP response. It is your responsibility to make sure
the files conform to the Prometheus exposition format. The only
modification done is to add a terminating newline to the file, is one
is not already present.

### `uname`

The `uname` collector exports data from the eponymous system call as
labels attached to the metric `node_uname_info`, which always has the
value 1. The attached labels are:

* `machine`
* `nodename`
* `release`
* `sysname`
* `version`

See your `uname(2)` man page for details of the values.